How to conveniently install and wire the Fire Electric Window Opener for the renovation of old buildings?
Publish Time: 2024-07-05
In the renovation project of old buildings, when installing the Fire Electric Window Opener to ensure fire safety, it is necessary to fully consider its convenient installation and wiring.
First of all, before installation, the structure of the old building should be surveyed and evaluated in detail. Understand the type, size, location of the window and the surrounding obstacles to provide a basis for selecting the appropriate window opener model and installation location.
For the selection of the installation location, the characteristics of the original building structure, such as window frames, window sills and other parts, should be used as much as possible to reduce damage to the wall. External or embedded installation methods can be used. External installation is relatively simple. Only brackets need to be installed on the outside of the window to fix the window opener; embedded installation requires slotting on the window frame or wall, but it is more beautiful and stable.
In terms of wiring, try to follow the original line direction and use pipes, wire troughs, etc. inside the building for wiring. If the original wiring channel cannot meet the needs, you can choose to lay the open line, but pay attention to the protection and beauty of the line, and use wire troughs or casings for covering.
In terms of power access, try to find existing power points nearby, such as lighting distribution boxes, to reduce the length of new line laying. If the distance is far and new lines need to be laid, the appropriate cable specifications should be selected to ensure stable power supply and meet safety standards. For some areas where wiring is difficult, Fire Electric Window Opener with wireless control technology can be considered, but attention should be paid to the stability and reliability of the wireless signal, and backup power supply should be equipped to deal with emergencies.
During the installation process, attention should be paid to coordination with other building facilities to avoid affecting the normal use of windows and the overall appearance of the building. In addition, in order to reduce the impact of construction on residents' lives, the construction time and construction sequence should be reasonably arranged to shorten the construction period as much as possible.
In short, when installing Fire Electric Window Opener in the renovation of old buildings, it is necessary to fully combine the actual situation of the building, carefully plan the installation location and wiring plan, and adopt appropriate technical means and construction methods to achieve convenient installation and wiring, while ensuring the performance and reliability of Fire Electric Window Opener, and improving the fire safety level of old buildings.